BRAND NEW- Keyence Light Safety Curtains GL-R40H Transmitter And Receiver Set
$2,000.00
- Description
- Additional information
Description
New Keyence GL-R4OH Safety Light Curtain Main Unit Hand-protection Type 40 Optical Axes
FAST SHIPPED AND BACKED BY WARRANTY!
Location WR291
Per the manufacturer
Specifications
Model
GL-R40H
Detection capability
ø0.98" ø25 mm
Beam axis spacing/Lens diameter
20 mm / ø5 0.79" / ø0.20"
Detecting distance
0.66 to 49.21' 0.2 to 15 m*1
Effective aperture angle
Max. ±2.5° (When operating distance is 9.84' 3 m or more)
Light source
Infrared LED (870 nm)
Response time (OSSD) (ms)
Wire synchronization, One-line or
Optical synchronization system (Channel 0)
ON→OFF
8.7
OFF→ON
51.9*2
All blocked→ON
71.8*3
Optical synchronization system
(Channel A or B)
ON→OFF
12.3
OFF→ON
57.2*2
All blocked→ON
85.8*3
Detection mode
Turns on when no interruptions are present in the detection zone
Synchronization between the transmitter and receiver
Optical synchronization or Wire synchronization (Determined by wiring)
Light interference prevention function
Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically
Control output
(OSSD output)
Output
2 transistor outputs. (PNP or NPN is determined by the cable type)
Max. load current
500 mA*4
Residual voltage (during ON)
Max. 2.5 V (with a cable length of 16.40' 5 m)
OFF state voltage
Max. 2.0 V (with a cable length of 16.40' 5 m)
Leakage current
Max. 200 µA
Max. capacitive load
2.2 µF
Load wiring resistance
Max. 2.5 Ω
Supplemental output
(Non-safety-related output)
AUX
transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)
Error output
Muting lamp output
Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.
External input
When using a PNP output cable
EDM input
Wait input
Reset input
Muting input 1, 2
Override input
ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
When using an NPN output cable
ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)
Power supply
Power voltage
24 VDC ±20%, ripple (P-P) 10% or less, Class 2
Current
consumption
(Max.) (mA)
Transmitter
65
Receiver
76
Protection circuit
Reverse current protection, short-circuit protection for each output, surge protection for each output
Additional information
Weight | 7.0 kg |
---|---|
Dimensions | 45 × 5 × 5 cm |
Brand | Keyence |
Unit Type | Unit |
Custom Bundle | No |
Model | GL-R4OH |
MPN | GL-R4OH |
Country/Region of Manufacture | Japan |
Unit Quantity | 2 |
Modified Item | No |
Condition | New – Open box |
Related Products
-
Other Facility Safety Equipment
*NEW* Simplex 0637664 Surface Mount Maintenance Switch w/ Disconnect *WARRANTY*
There is no AI review summary. -
Other Facility Safety Equipment
AUTOMATION DIRECT VFT1-A0-1M FAST SHIPPING! + WARRANTY
There is no AI review summary. -
Other Facility Safety Equipment
NEW OPEN BOX- Tapeswitch GUARDSTAR PSSU/1 Control Unit 110/230V~, 50/60Hz, 6VA
There is no AI review summary. -
Other Facility Safety Equipment
Railhead Forklift LED Safety Lamp Backup Lamp Lift Truck Warranty Fast Shipping
There is no AI review summary. -
Other Facility Safety Equipment
SCHNEIDER RED SIGNAL LIGHT XVB C2B4 NIB FAST SHIPPING! + WARRANTY
There is no AI review summary.
A Decade of 100% Positive Feedback
Over 60,000 items sold on eBay with 100% positive feedback